FlowSonic® GP

The FlowSonic® GP is the ultrasonic fuel flow meter of choice for use in IndyCar®. As the newest ultrasonic fuel flow meter in our on-vehicle motorsport range, the FlowSonic® GP features the latest upgrades including dual CAN bus output options for teams and governing bodies to read data on separate channels.

Measurement Performance

± 8000 ml/min

Operating Flow Range

2.2 kHz

Measurement Rate

±0.05% of reading

Highly accurate and repeatable

Dual CAN

Communications Output

-20°C to +120°C

Temperature Range

Low latency

Real-time measurement

Compact & Lightweight

For easy installation in race vehicles

50 kPa to 2000 kPa

Operating Fluid Pressure

Engineered to ensure ultimate fuel consumption monitoring, the FlowSonic® GP is a versatile on-vehicle flow meter implemented for fair competition and surveillance by governing bodies. The IndyCar® fuel flow meter of choice.

Engineered for Precision Performance in Race Cars  

The FlowSonic® GP is the ultimate motorsport flow meter, delivering precise fuel and fluid measurements with ±0.05% accuracy. Its compact, lightweight, and vibration-tolerant design makes it ideal for demanding racing environments. This ultrasonic flow meter is built for performance.

A black Sentronics flow meter device with multiple ports and screw details, presented on a white background, highlighting its design and features.

Dual CAN bus Capability

Featuring the ability to run a second CAN bus, this new dual output option enables both teams and motorsport governing bodies to see real-time on-vehicle fuel consumption, with the option for encryption.

Product Specification

Measurement Performance

Measurement rate

2.2 kHz

Repeatability

± 0.05% of reading

Uncertainty*

± 0.25% of reading

Operating flow range

± 8000 ml/min (±480 LPH)

Calibrated measurement range

500-4000 ml/min (30-240 LPH)

Pressure drop @ 25ºC

5kPa @ 2000ml/min, 15kPa @ 4000ml/min (WEC)

Temperature measurement

2 x 1000 ohm RTD (1/3 DIN standard)

*Calculated according to ISO/TR using root-sum square method yielding 95% confidence

Flow Outputs and Functions

Calibrated volumetric flow rate (ml/min)

Calibrated cumulative volumetric flow rate (ml)

Calibrated mass flow rate (g/min)

Calibrated cumulative mass flow (g)

Max/min logging

Elapsed time counter (power on, ETI)

Run time (flow time, RTI)

Speed of sound (m/s)

Diagnostics via CAN

Data Security and Encryption

Firmware security check-sums

Mechanical

Dry weight

330 g

Fuel capacity

15 ml

O-ring seal elastomer

FPM fluorocarbon

Wetted materials

FPM, anodised aluminium alloy, stainless steel

Fluid operating pressure

50 kPa to 2000 kPa, 8000 kPa maximum burst

Fuel line connectors

-6AN ttings 9/16-inch UNF thread

Electrical

Voltage

8V to 30V DC

Current

< 95mA @ +12V DC

Voltage protection

Over-voltage 45V DC, reverse polarity -45V DC

Deutsch sensor connector

ASDD006-09PD-FI-952K

Deutsch mating connector

ASDD006-09PD-FI-952K

CAN Communications

Design standard

ISO 11898-2 (high-speed applications)

Message format

2.0A (11-bit identifer)

Baud rate

1 Mbit/sec

CAN termination resistor

No

Conguration interface

3.3V serial interface

Fuel Compatibility

Pump petrol or diesel

F1® petrol blends

Methanol/petrol blends

WEC standard bioethanol/ETBE blend

Ethanol/petrol blends

IMSA standard E20C

Neat butanol, methanol, or ethanol

IMSA standard E10

Sustainable biofuel

Environmental

Storage temperature

-40ºC to 85ºC

External pressure rating

300 kPa

Calculate your Flow Rate  ●  Go to the Flow Rate Calculator  ●